FluxEDA Changelog
[0.9.9.3-beta] - 2026-10-14
Important
- A design that simulated in 0.9.9.2 may stop at the netlist - FluxEDA 0.9.9.3 checks designs more strictly. The netlist, a simulation, a sweep or a margin analysis stops, with a message that names what to change and how, when the design has: names with spaces or signs such as . , ( ) =, or names that differ only in case (R1 and r1); an absolute or drive path in control.inp (C:\..., /home/...): name the file relative to the cell's josim folder; a BIAS symbol on a GND net; a junction card with a word JoSIM does not read as written (for example ICRIT= on the card), so that JoSIM would run another model; a JJ model that a cell defines and the top level defines again with other values (for example in control.inp), because which one JoSIM uses can differ between Windows, macOS and Linux; a net named like an element of the same schematic, for example the net VBIAS and a voltage source named Vbias: rename the instance in Properties; several JJ models and no default in the technology library; or a cell whose saved subcircuit no longer matches its schematic: open the cell and save it once
New Features
- Projects - A project file (.fluxproj) keeps its own library list: one project per design, or one in a shared folder so a whole team works with the same libraries. File > Projects... lists your recent projects; the File menu also has New Project..., Open Project..., Open Recent Project, Close Project and Save Library List as Project.... Libraries inside or near the project folder are stored with relative paths, so a shared folder works on every computer. Without a project, FluxEDA uses your personal library list as before
- First start - A new installation asks for the working folder and then for your first project: create one, open one, or skip and keep a personal library list. Updating an existing installation does not ask
- Deactivate, Short and Activate - Edit > Deactivate (Open) leaves the selected instances out of the netlist without deleting them; they are drawn faded. Short leaves a two-pin instance out and joins its two nodes. Activate brings them back. The commands are also in the right-click menu and in Properties (Netlist field), and the state is saved with the schematic. GND and BIAS symbols cannot be deactivated or shorted
- InOut ports - Create > InOut Port (Ctrl+Shift+P) places a bidirectional port, named IO1, IO2, ...; ERC and timing analysis treat it as bidirectional, and a symbol made from the schematic gets an InOut pin
- Node voltage probes - Probe Setup lists the circuit's nodes, also inside cells, with what each node connects to. The waveform viewer shows them as V(node)
- Open saved sweep results - Simulation > Open Sweep Results... (SIMULATION ribbon: Sweep Results) shows the last finished parameter sweep again without simulating. If the design changed since the sweep, FluxEDA says so and asks first
- Sweep runs per subplot - In the Waveform Viewer, turn off Apply to all plots to choose which sweep runs each subplot shows. Save State keeps the choice and it comes back when the sweep results are opened again; if the sweep's runs changed since, a note names the runs that are gone, the new ones and the ones shown
- Paste Keeping Names - Ctrl+Shift+V (Edit > Paste Keeping Names, EDIT ribbon: Paste Names) pastes with the copied wires' net names, so they join the nets of those names on purpose. With Ctrl+V, a copied net that touches no existing net gets a new name (sig becomes sig_1)
- Turn a selection as a group - R, X and Y turn the whole selection about its centre as one undo step; selected wires turn with it and stay on their pins. Before, each item turned in place
- JJ count - The Library Manager shows the JJ count of a design as the netlist builds it: every JJ, with each cell counted once per instance; deactivated instances are not counted
- Test This Build - In a nightly build, Help > Beta-Tester / Nightly Builds opens a window that lists what to test in that build and how. Mark each item and send one report
- Request a license extension - When your license has expired, or will expire within 7 days, FluxEDA offers to request an extension; the license dialog has Request Extension... for an expired key
- Cell Selector remembers - Placing an instance opens the Cell Selector with the library and category it showed last and selects the cell you placed last when it is in that category
- Symbol Attributes are saved - Format, Description, Author and Version set in Symbol Attributes are saved with the symbol and shown again when you open it; before, they were lost when the editor closed
Fixes
- Long simulations - A simulation is no longer stopped after 5 minutes; it runs until JoSIM finishes, and Cancel in the progress window stops it
- JoSIM on Windows - Windows now runs the same JoSIM as macOS and Linux (2.7). Before, Windows had an earlier build, and a sine source with a delay written in a control file could simulate differently there
- Simulation output file - When the output file of a run (for example .file output.csv) cannot be read, for instance because another program holds it open, Simulate stops before JoSIM starts and says that the file could not be read; before, it said the file had changed. On Windows FluxEDA waits up to 2 seconds for a file another program holds. A run cleans up only the temporary files it made itself
- Files held for a moment on Windows - When Dropbox, OneDrive or a virus scanner holds a file for a moment, Save, the simulation result and cell locks wait for it (up to 5 seconds) instead of failing with "The process cannot access the file because it is being used by another process"
- Waveform Plotter - A single subplot fills the window when the Plotter opens; before, it took only the top third
- Simulation Failed - The note about deactivated and shorted instances appears only when the simulator reports "Matrix is singular"; before, it was added to every failed simulation of a design with such instances
- Saving a new schematic - Save of a new schematic starts in your first own library, not in the libraries that come with FluxEDA. Save As writes into a cell folder of a library in your list; a name given in the library folder itself offers to make it a new cell (Save as Cell). Any other folder is refused with how to add its library. The Symbol Editor does the same
- Unsaved changes in cells - Simulate, Generate Netlist, Netlist & Simulate, Add Probe, Parameter Sweep and Margin Analysis first ask to save the open cells with unsaved changes (Save and Continue, or Cancel); before, the netlist used the saved cells without saying so
- Parameter Sweep - A source offers the parameters of its type in the schematic; before, a source the Test Pattern Generator had made PWL was offered as a DC value and the sweep stopped. A saved sweep row whose parameter the source no longer has is not run, and a note says why
- Empty names - New Library and the name commands of the Library Manager say when the name is empty; before, they closed without a word
- Test Pattern Generator - A schematic without a voltage source gets a note: the generator edits voltage sources only
- License and preferences files - A license or preferences file that could not be read for a moment is no longer written over, or offered for deletion as damaged
- Probes not in the netlist - Before a simulation, FluxEDA names the probes whose device or node is not in the netlist (for example after the instance was deleted or deactivated) and asks whether to run without them; before, JoSIM stopped with Unknown device/node. A node probe whose node has the name of an element is refused before the run
- Messages - Every message that refuses a command now says what was not done, why, how to fix it (with the menu command to use) and whether anything was changed
- Dragging cells - Wires follow and stay connected, also at T-junctions made by a wire's bend, at pins that touch directly with no wire between them, and at clock labels. Esc during a drag puts everything back; dragging back to the start changes nothing and adds no undo step
- Wire segment drag - T-junction branches on the moving part follow it. A segment drag that would lose a connection or join another net is not done and the status bar says why; Esc before the release takes it back
- Drawing wires (W) - A corner FluxEDA adds for you never touches another net; if both directions would, the click is not taken and the status bar says why. A click on a wire ends exactly on that wire, so what shows as connected is connected. Enter and double-click keep only the points you clicked
- Pins on the middle of a wire - A pin, port or clock label that you drop, place, paste or turn exactly onto the middle of a wire splits the wire there and connects to it. A pin that only lies there in an older file stays unconnected, and ERC warns about it
- Copy and paste - Copies keep rotation, colour, properties and text labels; clock labels can be copied; two pasted ports never get the same name; a pasted instance keeps its library. Each copy or paste is one undo step. A mutual inductance (K) copied together with its two inductors couples the copies; a K copied alone keeps the names of the inductors it couples; a K copied with only one of its inductors is not copied, and the message says why. Ctrl+C is not started while a copy, move, drag or placement is under way; the status bar says why. Clipboard content with a K and inductors whose names were not copied (from an older FluxEDA) is not pasted; copy the parts again
- GND and VBIAS net names - Follow the connections after every edit, in that edit's undo step: a net connected to a GND or BIAS symbol is named GND or VBIAS, and a net cut off from it loses that name
- Undo and Redo - Undo puts every item back exactly where it was, so a file saved after Undo is the same as before the edit. An edit, Undo or Redo that fails is taken back whole and is not counted as done
- Properties - Every change in Properties is one undo step (a new rotation or a shape's size could not be undone before), and OK or Apply without a change adds no undo step and leaves the file as it is. A new position, rotation or cell is checked like an M move
- Netlist - Two different nets never become one simulation node. Before, a net you named 1 could share node 1 with an unnamed net. Net names that differ only in case, a net named like ground that is not on a GND symbol, and a pin on no net now stop the netlist with a message naming them. A mutual inductance (K) must couple two existing inductors. Two instances that would get the same element name are refused. Two K elements that couple the same two inductors stop the netlist. A call in a subcircuit file may name its subcircuit anywhere on the line (Xjtl1 1 2 5 jtl, as the c2j cells write it); a call that names no subcircuit or more than one, and a net named like a subcircuit of the netlist, stop the netlist with a message naming the line. A net may not have the name of an element of its schematic (the net V1 and the source V1), because the simulator would read V(V1) as the source's voltage; the editor refuses such a name
- Junction values - The Icrit of a JJ model is read as JoSIM reads it (a value without a unit is in amperes; before, Icrit=1e-4A gave a junction area 1000 times too large). Ic or IcRs that is zero, negative or not a number stops the netlist instead of being replaced by the default. Area and shunt resistance are written with 6 significant digits. A JJ model that gives Icrit twice, or Icrit and IC, stops the netlist. A junction card whose model JoSIM would read otherwise than it is written (ICRIT= on the card, an extra word, no model) stops the netlist, a sweep and a margin analysis
- JJ model choice - The JJ model is chosen automatically only when it is not ambiguous. With several JJ models and no default in the technology library, a JJ without its own model stops the netlist with how to choose one; before, the first model file was used
- Cells inside cells - A cell whose saved subcircuit no longer matches its schematic stops the netlist and names the cell; before, the old subcircuit was simulated. A copied cell now also works when it is placed inside another cell
- Test Pattern Generator and Transient Settings - Apply and OK write only what you changed; the other sources and the .tran values you did not change stay exactly as they were. A value either window cannot read is named and nothing is applied
- Simulation control files - FluxEDA reads them as JoSIM does: the last .tran counts, nothing after .end is read, lines starting with + continue the line before, the first .param of a name counts, include and end are read also without the dot, and a line starting with # is a comment. Add Probe writes its lines before .end
- Simulation inputs - Simulate, sweeps and margin analysis run JoSIM on copies of the netlist, control.inp and the files they include, exactly as FluxEDA checked them, so a file changed during the run cannot reach JoSIM. An include loop or a folder that cannot be written stops the run before it starts and the message names it
- Margin Analysis - Changes exactly the value it reports (before, a resistor line could be edited in the wrong place, and a margin was reported for a change that was never simulated). Pulses are counted on junction phase outputs only, and a design without a phase probe gets a message saying how to add one. A run whose output cannot be read, or stops before the end time of .tran, is reported instead of being counted as a failing circuit. The VBIAS row changes the source that drives the cells' bias node, and only that source; before, it could change another DC source of the testbench. A circuit with no bias port has no VBIAS row. When the bias cannot be swept (no source or several on the bias node, a pwl ramp), the results say why and the other values are analysed. A value of the circuit under test that names a .param of the testbench is swept on its own line. FluxEDA could crash now and then when the results of an analysis were shown; it no longer does. An input whose meaning depends on details of how JoSIM reads it (a subcircuit the analysis uses defined more than once, a card written over two files, element lines in a .control block inside a subcircuit, a .subckt without .ends) stops the analysis before any run, and the message names the file and line and how to write it plainly. A card that gives a value twice, or a junction's AREA together with IC, stops the analysis; a junction sized by IC alone is named as not swept. A value is swept only where JoSIM applies it (for example a junction's SPREAD only before AREA or IC); the results name the others as not swept
- Parameter sweep - Every sweep runs in a new, empty folder with the files its netlist includes (before, an include removed from the design could still be simulated from an earlier sweep). Each step's netlist gets the exact step value. A new sweep replaces the saved results only when it is complete (every run reached the end time of .tran), and the sweep settings change the schematic as one undo step. A JJ model that gives Icrit twice, or a card written over two files, stops the sweep before it starts. So does such a card, or a junction whose shunt resistor is not across the junction. A value written as an expression over several words, for example {25 * 2}, is changed as a whole
- Waveform viewers - Export > CSV writes the curves shown on the screen (before, it wrote the first sweep run of each checked signal, whatever was shown). A value in the simulation output that cannot be read is reported instead of being shown as 0, and sweep runs keep their own labels. Save State keeps the CLK Ref choice. In the Waveform Plotter an X-Y curve keeps all its points after a layout change or a removed subplot, and the cursor shows the same sample on subplots with different X axes, also after a filter on the X signal. Signal choices show the kind of the signal (V:BCLK, P:BCLK), so CLK Ref can switch between them
- Publication figure - Range Auto exports the time window visible in the viewer (what you see is what you export); Manual sets any other range. A Waveform Plotter subplot whose X axis is another signal is refused instead of being drawn against time
- Back-Annotation - Reads the netlist as JoSIM does (continuation lines, values with units such as area=2000m); a value it cannot read is shown and not applied. A junction's shunt resistor is the resistor across the junction's two nodes
- Save never writes over newer work - Save does not overwrite a schematic or symbol that changed on disk after you opened it (another user or a cloud sync); the message says so. The backup copy (.bak) keeps the file as it was when you opened it, not the one before your last save
- One window per file - Opening a schematic or symbol that is already open (Go Down, Edit Symbol..., Library Manager, Recent Files) brings its window to the front instead of opening a second editor of the same file
- Auto-save recovery - Changes you keep with Cancel at the recovery question are set aside and offered again at every later opening until you choose Yes or No. FluxEDA never writes over or deletes an auto-save you have not decided on, and a window deletes only the auto-save it wrote itself. Rename Cell and Rename Library move the auto-saves along; Delete Cell, Delete View and Delete Library say in their question when auto-saves go with them. A closed window never writes an auto-save again; before, it could write over the auto-save of the same schematic opened again
- Library Manager - Rename Library and Rename Cell are all or nothing. Paste Cell and Paste View replace an existing cell or view only with a complete copy. A library folder that cannot be written no longer crashes FluxEDA, and one that cannot be deleted is reported and stays in the list. Commands that change a cell take its lock, so a cell that is open elsewhere is not changed under it. Rename Cell renames the cell's own subcircuit definition and every call of it, wherever the call names it (also on a + line). Rename Cell changes only the subcircuit name in a call, never a node, and a cell name that would make a call name two cells is refused before anything is written (Rename Cell, Paste Cell, Paste View, New Cell)
- Cell locks - A lock file that is empty or cannot be read opens the cell read-only (Cell Lock Unknown); before, it could be taken for no lock. Save and the Library Manager commands write only after FluxEDA renewed the cell's lock; a lock another FluxEDA took over makes the editor read-only and the command says so. On drives without hard links (exFAT, FAT, some network shares) a cell opens for editing without a lock and FluxEDA says that multi-user editing is not supported there; before, it opened read-only. A lock now belongs to the computer itself, not to its network name: a laptop that moves to another network keeps its open cells (before, the editor could turn read-only and Save was refused). A lock written by an older FluxEDA counts as another computer's until it is 15 minutes old
- Library list - When two libraries in the list have the same name, the first one is used everywhere and the conflict is reported. FluxEDA no longer writes lock or other files into the libraries that come with it
- Damaged library settings - A library whose settings file cannot be read is not loaded and the message names the file; before, it could be read as a library without categories or technology library
- Symbols with two pins of one name - The Symbol Editor opens such a symbol with both pins and refuses to save it until one is renamed; everywhere else it is refused with how to fix it, and ERC lists it as a pin sync problem. Before, one of the pins was dropped silently
- Symbol Editor - R, X and Y turn the shapes, pins and labels themselves, so the turn is saved (before, a turned symbol came back unturned after saving). Move Origin no longer shifts pin labels twice, and Move Origin and Set/Reset Color can be undone. A symbol with an ellipse whose width and height differ is not saved, because the symbol file stores circles only (before, it came back as a circle); the message says how to fix it
- Cell Timing Editor - Save writes the delays shown, also after swapping two rows that show the same rounded value
- Library Health Check - The libraries that come with FluxEDA no longer show warnings (primitives without a subcircuit, sink and zero without delays, the ERC record). Right-click a result to open the FluxEDA tool for it: the Cell Timing Editor, the schematic, the symbol or the subcircuit view; it no longer opens the subcircuit or symbol file in a text editor
- Tutorial library - Add Built-in... in the Library Path Editor copies the tutorial library (flux_demo) into your working folder again when it is missing; before, it added a path that did not exist
- Libraries that come with FluxEDA - Your library list now names them as bundled:<name> (for example bundled:flux), as projects do, so they keep working when FluxEDA is moved or updated. Before, the list kept the path inside the application; a library added while FluxEDA ran from its disk image was lost when the image was ejected. Such an entry is shown with [!]; Add Built-in... in the Library Path Editor replaces it
- Exports - Export CSV, PNG, SVG, Export Image, the publication figure and Save Log never write over a FluxEDA file; the message asks for another name. A failed export leaves the file you picked as it was
- Windows installer and files in use - When another program holds a file of the installed FluxEDA, the installer waits a few seconds and tries again. If the file stays in use, it names the program that holds it (or the file, when the program cannot be named) and says how to go on. Before, it stopped with "Error opening file for writing". Programs started from FluxEDA (a web browser, JoSIM, KLayout) no longer keep FluxEDA's own files in use after FluxEDA quits
- Windows: second start - Starting FluxEDA while a busy FluxEDA is running waits for it and sends one request; before, it could report that FluxEDA did not respond
- Crash reports - On Windows and Linux, an error after the first editor opened showed a "Critical error occurred" box and was not written to the crash log, so it was never reported; it now goes to the crash log and the crash dialog like any other. Each start records the FluxEDA version and time in the crash log, so a hard crash names the version and session it happened in. The crash dialog lists each report with the FluxEDA version and time that wrote it, and the report you send carries the version that crashed. A clean quit no longer leaves its start record behind to be offered as a crash report
- Quitting on macOS - Quitting FluxEDA (for example from the Dock) while editors are open no longer crashes
- Check for Updates - Says when it could not check (no connection, or an answer it cannot read) instead of reporting that you run the latest version
- Nightly builds - Help > Beta-Tester / Nightly Builds compares the published nightly with the build you run and never offers an older one
- License - A license now works through the whole of its expiry day (UTC). Without a connection FluxEDA uses the 7-day offline period; before, a start without a connection could be treated as a refused license. A license file whose expiry date or key cannot be read is named at start instead of being taken as a license without expiry
Known Issues
- Wire corners after a drag - Dragging a cell can redraw a connected wire instead of stretching it, and a corner can land off the grid. The connections are kept; the drawing may need tidying by hand
- Rotate and mirror - Rotating or mirroring a cell does not yet take its unselected wires along. The amber bar names the separated pins and its Undo button restores them. Select the wires together with the cell to turn them along
- Older FluxEDA versions - A schematic or symbol saved with 0.9.9.3 that uses Deactivate/Short or Symbol Attributes loses those settings if it is edited and saved with an older FluxEDA. Use 0.9.9.3 or later for these files
- Viewer state and older versions - A viewer state saved with 0.9.9.3 keeps the sweep run choice; FluxEDA 0.9.9.2 opens it without that choice and drops it if it saves the state again
- Library list and older versions - FluxEDA 0.9.9.2 does not read the bundled:<name> entries that 0.9.9.3 writes in your library list and shows those libraries as missing. If you go back to 0.9.9.2, add the library folder again with Add... in its Library Path Editor
- Old crash reports on Windows - FluxEDA versions before 0.9.9.3 never showed their crash reports on Windows, because the crash log could not be cleared while it was open. The first start of 0.9.9.3 can list those old reports once: each with the older FluxEDA version and time that wrote it, or, for a hard crash, as a report with no version or time. They are not crashes of 0.9.9.3
- Reserved words in names - PWL, PULSE, SIN, CUS, NOISE, PWS, EXP, DC and GND are reserved words, in upper or lower case. Do not use them inside the names of instances, of sources, of the nets a source connects, or of cus files (for example an instance named GND1, a source named VSIN1, a source net named pulse_in). Otherwise the simulation can stop or give wrong results without a warning. Cell names are not affected: a cell named sink is fine. FluxEDA 0.9.9.4 will refuse such names
- Cell pins on GND - JoSIM does not connect a cell pin that is on GND inside the cell to the net outside it. FluxEDA 0.9.9.3 does not write the subcircuit of such a cell when it is saved, and a design that uses an older subcircuit of it stops with "Matrix is singular" when the outside net has no other path to ground. Remove the GND from the pin's net inside the cell and connect the net outside the cell to GND. FluxEDA 0.9.9.4 will connect such pins to ground by itself
[0.9.9.2-beta] - 2026-10-08
Important
- No more "Bad Image" error on Windows - FluxEDA no longer loads the layout library when it starts. On Windows 11 with Smart App Control, earlier versions could show a "Bad Image" or "Part of this app has been blocked" message at every start. The preview Layout Editor is not part of this edition; opening a layout view shows a short message instead
New Features
- Recover unsaved work - Each open schematic now has its own autosave file. If FluxEDA closes unexpectedly, the next time you open that schematic it offers to recover your unsaved changes (Yes = recover, No = discard, Cancel = decide later)
- One FluxEDA at a time - Starting FluxEDA again while it is already running brings the open window to the front instead of starting a second copy
Fixes
- Cell locks - Another FluxEDA window can no longer take over a cell you are editing. If your lock is lost (for example the cell was taken over on another computer), the editor becomes read-only, tells you once and lets you Save As a different cell, so no one's work is overwritten. A schematic and its symbol share one lock, so closing one no longer unlocks the other
- Damaged files - A file that cannot be read (for example half-synced by a cloud folder) no longer crashes FluxEDA. If it is the symbol of a cell placed in a schematic, the schematic still opens: that cell is shown as a grey placeholder, a warning bar names the damaged file, and netlist and simulation wait until the file is repaired and you click Check Again. Opening a damaged schematic or symbol directly shows one message naming the file, and the cell is not left locked
- Changed outside FluxEDA - Renaming a library or a cell no longer makes its files look "changed outside FluxEDA". When a file really was changed outside FluxEDA, a short note appears in the status bar instead of a dialog
- Update notice - The update window lists only the most important changes; View Release Notes shows the full list
[0.9.9.1-beta] - 2026-10-08
Important
- Signed Windows installer - The Windows installer and FluxEDA itself are now digitally signed by PHI0 KUANTUM TEKNOLOJILERI ANONIM SIRKETI. For a while Windows may still show a SmartScreen notice for new versions; check that the publisher is PHI0 KUANTUM TEKNOLOJILERI ANONIM SIRKETI, then choose "More info" and "Run anyway"
- Current source symbol - The arrow now points the way the current flows in simulation (out of the n terminal), and a "+" marks the p terminal. Your designs simulate exactly as before; only the drawing changed, so existing current sources may show the arrow the other way round
- Connections are checked exactly - The connectivity check (ERC), the netlist, timing analysis and net tracing now use one rule: a pin or wire end is connected only when it sits exactly on the other pin, wire corner or wire. Before, the check accepted ends up to 10 units apart while the netlist did not, so a design could pass the check and still be simulated with an input left open. Such gaps now show as open pins; fix them by moving the wire end onto the pin. Two outputs (or two inputs) wired together are now reported again before the netlist is generated; you can still choose to generate it anyway
- Opening a schematic no longer changes it - FluxEDA no longer moves parts, renames GND/VBIAS nets, adds hidden wires or joins nearby wire ends when it opens a schematic, so a design opens exactly as it was saved and is not marked as modified. The false "Corrupted wires" warning on save is gone. A few designs whose wires only looked connected in the editor now show those pins as open in the connectivity check; move the wire end onto the pin to fix them
- Missing libraries no longer delete parts - If a library or cell cannot be found when a schematic opens, its parts are shown as grey dashed placeholders with a warning bar instead of disappearing, and saving keeps them unchanged. Right-click a placeholder to locate the library or replace the cell. Netlist, ERC and simulation wait until every part is found
- Simulation always uses the current design - Simulate, Probe, Parameter Sweep and Margin Analysis now check that the netlist matches the design, including unsaved edits and changes inside the cells it uses. If it does not, FluxEDA offers to regenerate it first; before, an old netlist could be simulated and give results for an earlier version of the circuit
- Hierarchical netlists - A cell placed from your own schematic is now connected in its port order, whatever the pin order of its symbol; before, inputs and outputs could be swapped in the netlist. Library cells whose bias pin is not the last one get the bias on the right node. The same cell name from two different libraries, or a cell that cannot be found inside a hierarchy, now stops netlist generation with a message instead of producing a wrong netlist. Simulate again any hierarchical design you rely on
- Parameter sweep results - Sweeps of resistors, inductors and capacitors with default names (I1, I2, ...) now really change the value; before, every step simulated the same circuit and still reported success. Junction Ic sweeps run (they stopped with an error), and IcRs sweeps give the right shunt resistance for junctions named B... Invalid values such as "2,5m" or an empty field now stop the sweep with a message instead of running as 0
New Features
- Beta-tester builds - Help > Beta-Tester / Nightly Builds lets you request access to frequent test builds, offered next to the regular release
- Tutorial library - FluxEDA now includes the flux_demo tutorial library (Josephson junction, SQUID and SFQ examples). On first start it is copied into your FluxEDA working folder and added to the library list, so you can simulate and edit it; your own copy is never overwritten
- Close previous waveform viewer - New option in Settings > Simulation closes the previous results window when a new simulation finishes
- Simulation can be cancelled - Simulate runs in the background with a Cancel button, so the window no longer freezes during long simulations. Cancel in Parameter Sweep and Margin Analysis stops the running simulation at once, and closing these windows during a run no longer crashes FluxEDA
- Refresh from Disk - New View > Refresh from Disk (Shift+F5) reloads the schematic from its file, for example after someone else changed it; it asks first if you have unsaved changes
- Classic menus by default - New installations start with the classic menu bar; the Ribbon can be chosen on first start or later in Settings. Your current choice is kept
Fixes
- Labels on rotated parts - Names, values and pin names of resistors, inductors, capacitors, junctions and sources no longer overlap at any rotation or mirror; pin names stay upright next to their pins
- Subplot layout - The Layout box always shows the real arrangement (for example 4x1); deleting a subplot keeps the others stacked, and saved views reopen with all their subplots and signals
- Waveform cursor - The cursor shows the correct values everywhere; values were missing or wrong after zooming in
- Parameter sweep - Shows the junction's actual critical current as the current value and starting range (it always showed 0.1 mA)
- Symbol editor pins - Changing a pin between input and output is saved, can be undone, and the pin label stays in place; moving a label or a pin name in Properties works and can be undone
- Auto-size symbol - New symbols from a schematic fit all pins; with many pins on one side the last ones were outside the symbol
- Symbol editor - Saving a built-in symbol keeps its label positions for rotated placements
- Library browser - No more crash when choosing Delete or Properties on a cell or view while the list refreshes
- Grid and Snap - The ribbon buttons and menu items stay in step with the G and Ctrl+G shortcuts; the first G press now works, and in the symbol editor G shows the grid again
- Zoom - The mouse wheel can always zoom back after zooming beyond the limit with the zoom buttons or Fit
- Ribbon in dark mode - The collapse and help icons are visible, and Help opens the User Guide
- Ghost components - Placing a part with a single click and pressing Ctrl+V twice no longer leave invisible "ghost" components behind; pasted parts appear one grid step away from the originals
- Closing FluxEDA - Closing the main window now asks to save any unsaved editors and then closes every FluxEDA window; choosing Cancel keeps FluxEDA open (before, editors and result windows could stay open)
- Results window position - The simulation results window no longer moves up each time it reopens; its title bar stays on screen and it fits smaller or scaled screens
- Design Summary - Shows and edits the junction's actual critical current and IcRs; edits made there now reach the simulation. The unused area field was removed
- Mutual inductance - Renaming an inductor now asks whether the mutual inductance (K) elements that couple it should follow the new name
- Wire connections - A wire end that shows as connected while drawing is connected when you finish; wires to GND and BIAS are recorded as connected and snap onto the pin
- Margin Analysis - A testbench whose include file is missing or outside its folder now stops with a message saying how to fix it; before, the include was dropped silently and the margins were computed for a different circuit. Two analyses can run at the same time. The window reminds you that margins are measured against the nominal run, and warns when the nominal run produced no pulses
- Simulation results - A simulation that did not write new results is reported as failed instead of showing the previous results
- Rotated and mirrored parts inside hierarchical cells - When a cell is netlisted from its schematic, parts that are both rotated by 90 or 270 degrees and mirrored are now connected exactly as drawn; before, their pins could land on the wrong side
- Redraw - Redraw (F5) no longer removes text annotations, clock labels or port rotation, which were then lost on save. Undo works after Redraw and after reloading a schematic (it could crash or leave parts that were shown but not saved). Opening another schematic no longer carries over the previous design's sweep settings, and annotation colours are kept
- Clock labels, text notes and Undo - Undoing the placement or deletion of a clock label now also undoes it in the saved file, and a deleted text note is no longer saved; before, both came back when the schematic was reopened. Moving a clock label (or a text note together with other parts) can now be undone; before, Undo reverted the previous, unrelated action
- Moving parts with clock labels - When clock labels are moved together with other parts (Select All and drag, or 'm'), wires now move by the same amount; before, they could jump to a wrong place. Undo after a move restores every wire end, including pin-to-pin markers, and Redo no longer marks ordinary wires as pin-to-pin. A text note dragged on its own can be undone
- Open Recent - Opening a recent schematic now asks to save unsaved changes first; before, they were lost
- Clean Dangling Wires - A wire whose end is only a few units away from a pin is no longer offered for deletion; it is listed with the instruction to move the wire end onto the pin. Two outputs (or inputs) wired together are reported once instead of twice
- Simulate while running - Simulate and Netlist & Simulate are greyed out until the running simulation ends. Cancelling a parameter sweep no longer shows an error, and a new sweep cannot be started until the cancelled one has stopped
- Missing junction model - When a design uses a cell whose junction model is not in the design's technology library, the message now lists the cells and instances that need it, which technology libraries define it, and how to fix it by hand (replace the cells, or move the design to a library of that technology, with the number of other designs a tech_library change would affect)
- Netlist warnings - Each warning is shown with its own explanation instead of a fixed note about default values
- Library list - A library that comes with FluxEDA (such as flux) stays removed or disabled when you remove or disable it; before, it came back at every start. Saving the library list no longer erases other settings such as a custom JoSIM path
- flux library - The spll cell's bias wire no longer shows as dangling, so Clean Dangling Wires no longer offers to delete it
- Safer saving - If saving fails (for example a file locked by antivirus or cloud sync), the previous schematic stays intact; before, it could be left missing. Netlists and simulation control files are written the same safe way
- Windows installer - The installer no longer closes a running FluxEDA by force, which lost unsaved work. If FluxEDA is open, it asks you to save and close it, then click Retry
- User Working Folder - Settings > Change User Working Folder... and Show User Working Folder are back in the main window (they had disappeared from the menu)
- Probes inside cells - The probe dialog now lists and probes elements inside cells placed within your own cells, at any depth; before, those cells showed no elements
- Design Manager - The value format help for junctions shows Ic and IcRs instead of the removed area field
[0.9.9.0-beta] - 2026-04-16
New Features
- Netlist & Simulate (F9) - One-click netlist generation + simulation
- Clean Dangling Wires tool - Remove wires with open endpoints (Tools menu)
- Reset Configuration - Fresh start from Help menu (clears all settings)
- Probe labels in viewer - Labels set in probe dialog appear in waveform viewer automatically
Fixes
- Wire system overhaul - Fixed MoveALL alignment, segment drag diagonals, visual selection on Ctrl+A, T-junction consolidation
- GND/VBIAS net naming - Stale names no longer cause shorted nodes in simulation
- Grid per schematic - Grid saved/loaded from schematic file, persists on grid change
- Repair wires - No longer creates diagonal wires (metadata-only, zero point movement)
- SSL certificate fix - License activation works on all macOS machines
- Bundled libraries - Auto-registered on fresh install and upgrade
- Subplot layout - Closing a subplot properly resizes remaining plots
- Dark mode - Axis labels and grid no longer disappear on layout change
- Probe dialog - Visible checkboxes, zebra rows, sorted by component type
- Lambda seat race - Fixed license activation race condition
- 43 code review items resolved
[0.9.8.12-beta] - 2026-04-11
New Features
- Hierarchical subcircuit generation - User cells now generate proper `.subckt` definitions instead of flattening. Supports nested hierarchies (cell A contains B contains C)
- I/O port indicators - Input/Output ports now show connection indicator dots and selection highlight rectangles, matching cell pin behavior
Fixes
- Undo ghost fix - Undoing instance placement no longer leaves invisible data in saved files
- BTB wire persistence - Back-to-back pin connections now survive save/reload correctly
- Pin sync check - ERC and Library Health Checker detect when symbol pins don't match schematic ports
- Netlist staleness detection - Uses content hash instead of file timestamps (cloud-sync safe)
- Subcircuit bias ports - VBIAS port only added to cells that actually need it (no unnecessary ports on passive cells)
- Waveform viewer state restore - Missing subplot assignments handled gracefully instead of crashing
- Subplot shrink dialog - Layout shrink now asks whether to move or remove signals
[0.9.8.11-beta] - 2026-04-10
Fixes
- Library path comments - Commented-out library paths (with * prefix) no longer cause "Symbol not found" errors in properties dialog, startup, and config migration
- Pre-conference hardening - Library cleanup, crash fixes, build safety improvements
- Lambda seat race - Fixed license activation race condition when multiple machines activate simultaneously
- NSIS installer - Stale .pyd files cleaned up during Windows install
[0.9.8.10-beta] - 2026-04-08
Fixes
- License activation resilience - Better handling of HMAC signature changes across upgrades, retry on network failure
- Clean Dangling Wires tool - now correctly detects and highlights dangling wires in red before removal
- Bundled libraries - primitives and flux libraries auto-registered on fresh install and upgrade
- Drag crash fix - Fixed NameError in movement controller on cell drag
- Probe dialog - Zebra striping, visible checkboxes, sorted by component type
- Probe labels - Unified with viewer signal names (single file, bidirectional)
[0.9.8.9-beta] - 2026-04-08
New Features
- Netlist & Simulate (F9) - One-click netlist generation + simulation. No more separate steps
- Wire visual selection - Ctrl+A and rubber band now visually highlight wires (was invisible before)
- Grid per schematic - Grid size saved/loaded from schematic file. Each design keeps its own grid
Fixes
- Stale GND/VBIAS net names - Wires disconnected from GND/BIAS primitives no longer keep wrong names. Fixes shorted nodes in simulation (FE-0050)
- MoveALL wire alignment - Ctrl+A drag no longer shifts wires 5-10px from pins
- Wire segment drag - Dragging first/last segment of a wire no longer creates diagonal lines
- Dark mode layout change - Axis labels and grid no longer disappear when changing subplot layout in dark mode
- Subplot close - Closing a subplot (X button) now properly resizes remaining subplots to fill space
- Close button crash - Fixed crash when changing subplot layout (C++ object lifetime)
- QCursor crash - Fixed crash on right-click in Waveform Plotter
- Custom source type - Renamed "cus" to "custom" in source type dropdown. Old schematics auto-migrated
- Grid size dialog - Grid minimum lowered from 10 to 2. Fixes alignment for schematics designed with grid=5
- Zero-length wire cleanup - Degenerate wires (all points identical) removed on load
Internal
- Wire system overhaul: `update_point()` prevents Qt rendering artifacts, T-junction detection consolidated, tolerances unified and derived from grid size
- All netlist/simulation error paths show dialogs (no silent failures)
- GND/VBIAS rename tracked in undo stack
[0.9.8.8-beta] - 2026-04-06
Important
- New default viewer. Simulation results now open in the Waveform Plotter with grid layouts and X-Y plot support. The SFQ viewer (with clock markers and pulse counting) is still available via the "SFQ Viewer" button in the toolbar, or change the default in Settings > General.
New Features
- Waveform Plotter - Grid layout selector (1x1 to 3x2), per-subplot X-axis for IV curves and SQUID characterization, custom signal names, active subplot zoom
- Viewer selection - Choose default viewer in Settings > General (Waveform Plotter or SFQ Aware)
- Side-by-side viewers - Open both viewers at once with toolbar buttons
- Shared signal names - Rename a signal in one viewer, both viewers use the same name
- Clock Labels - Press K to place a clock signal marker on any net. Replaces name-based clock detection with explicit marking
- Crossing cell channels - Define independent signal paths for crossing cells in the Timing Editor
- SFQ unit defaults - Bare numbers in test pattern dialog default to picoseconds and millivolts
- ERC cloud sync support - ERC status no longer shows false "outdated" warnings on Dropbox
Fixes
- Signal tracing uses explicit cell type data instead of guessing from cell names
- Signal trace loads timing data correctly on first use
- Tech library detection reads the library type directly instead of searching for files
- Case-insensitive BIAS cell handling
- macOS configuration moved to the correct system location with automatic migration
- Empty shunt resistor value (IcRs) blocked in properties dialog
- Better error messages for margin analysis
- Hardcoded default values removed (IcRs, Icrit) - reads from technology library
- DUT selection is now explicit (no auto-detection)
- Viewer windows appear in Windows taskbar
- All viewer windows close when the schematic editor closes
- Simulation progress dialog no longer shows blank on Windows
- Probe dialog warns when the netlist is outdated
- "VBIAS" blocked as a net name (conflicts with internal bias net)
- Better status bar messages in trace and timing modes
- Multiple crash fixes and stability improvements
Documentation
- Help updated: Waveform Plotter, reserved net names, viewer settings, SFQ units table, clock labels, signal tracing
- Quick start updated: viewer mode selection, clock labels
- Full assumption audit completed (66 items reviewed)
[0.9.8.7-beta] - 2026-04-06
New Features
- Clock Labels - Press K to place a clock signal marker on any net. Replaces name-based clock detection
- Crossing cell channels - Define independent signal paths in the Timing Editor
Fixes
- Signal tracing uses explicit cell type data instead of guessing from cell names
- Tech library detection reads the library type directly
- Case-insensitive BIAS cell handling
- macOS configuration moved to correct system location with automatic migration
- Empty IcRs blocked in properties dialog
- Better error messages for margin analysis
- Reserved net names enforced (bias, gnd)
- Version update ordering fixed for pre-release tags
- Multiple crash fixes
[0.9.8.6-beta] - 2026-04-05
New Features
- Back-annotate review table - Full comparison table showing schematic vs netlist values. Green for matched, white for changes, red for unmatched
- Timing analysis improvements - Blocked path indicator with color coding. Actionable dialog with fix instructions when cell has no timing data
- Timing Editor redesign - Cell type dropdown (wiring, clocked, source, sink, other) replaces checkbox
- Library health checker - ERC status, timing data, and subcircuit checks. Access from library right-click menu
- Cell selector overhaul - Cadence-style single-click placement with ghost preview. Stays on top during placement
- Per-user licensing - License tied to username, supports shared servers
Fixes
- Back-annotate formula corrected (was off by 10x)
- Back-annotate writes Ic (source of truth) instead of area (derived)
- Connectivity check validates pin positions after move operations
- Mirror fixed: uses cell origin instead of pin center
- Timing labels centered inside cells
- Cell colors persist across redraw
- Ghost preview follows cursor correctly
- Dark/light mode consistency improved across all dialogs
- Save+ERC shortcut added to ribbon toolbar
[0.9.8.5-beta] - 2026-04-04
New Features
- Library manager preview panel: Symbol and schematic thumbnails in the View column, click to preview
- Cell info panel: JJ count (with hierarchy traversal), timing data, margin chart thumbnails
- Save+ERC action (Ctrl+Shift+D): Save and run ERC in one step, records ERC status per cell
- ERC status tracking: Library manager shows ERC passed/failed/outdated per cell
- ERC pre-flight check: Warns about subcell ERC issues before simulation
- ERC placement warning: Warns when placing cells with failed or outdated ERC
- Margin analysis improvements: Auto-loads testbench from schematic, simulation count estimate, filtered thumbnails with threshold, baseline explanation
- Margin chart in library manager: Auto-saved thumbnails show constrained parameters, click to enlarge full chart
- Cell timing editor: Accessible from cell right-click, redesigned UI with tooltips, Save/Close/Clear buttons
- Cell selector UX overhaul: "All" category, cross-category filter, symbol preview thumbnail, Cadence-style ghost placement (appears on cursor over schematic), selector stays on top during placement, ESC closes selector
Fixes
- Fixed progress dialog appearing before output overwrite prompt during simulation
- Fixed crash when timing JSON key has no underscore separator
- Fixed Windows file URI backslash in margin chart paths
- Fixed duplicate method name crash in timing editor
- Version now displays correctly in help and quickstart when running from source
- Per-user licensing: different users on shared servers get separate seats
- License key pre-filled in activation dialog for easy re-activation after update
- Seamless machine ID migration (no orphaned seats on update)
[0.9.8.4-beta] - 2026-04-02
Fixed
- Fixed crash on startup related to window position restore
[0.9.8.3-beta] - 2026-04-02
Fixed
- JJ model dropdown now always shows models from technology library
- JJ placement warns when no technology library is attached
- Netlist generation requires JJ model to be explicitly assigned
- Update notifications now work correctly for beta versions
- Waveform viewer and hierarchy windows appear in Windows taskbar
- Improved crash detection and reporting
[0.9.8.2-beta] - 2026-04-02
New Features
- Collaborative editing: Cell-level file locking with heartbeat, lock indicators in library browser, auto-reload for read-only viewers, crash recovery without wait
- Crash reporting: Automatic crash logs with optional one-click report to support
- Ticket feedback: Email verification buttons ("Bug is Fixed" / "Still There") for closed tickets
- Draft comments: Save ticket comments as draft, send later with status update
Fixes
- T-junction wires: cell drag and wire segment drag now preserve Manhattan routing and branch connections
- Clock triangle missing in template-created symbols (FE-0012)
- Template symbols not editable on first open (FE-0010/FE-0012)
- Grid performance and pin placement drop on mode switch
- File lock: atomic creation (no TOCTOU race), PID-based fallback, 15-min stale timeout
- Crash guards in wire drag loop and airwire cleanup
- Graceful lock manager shutdown on app exit
[0.9.8.1-beta] - 2026-04-01
Security
- Fix HTML injection in Lambda download error page, confirm email, and admin notification
- HMAC key now per-machine (silent migration from old format)
- Lambda DynamoDB scans now paginated (handles >1MB results)
- Atomic ticket ID generation (no more race conditions)
Fixes
- Narrow broad exception handlers to specific types (6 locations)
- Atomic file writes for josim.json, model files, and schematics
- Platform-aware temp directory (D:/ check + fallback)
- Stale config path in simulation settings
- Null guard on design summary table item
- Netlist generator recursion depth limit (max 50)
- Documentation corrections (menu paths, shortcuts, waveform controls)
[0.9.8.0-beta] - 2026-03-30
New Features
- Pin-to-pin connection markers: Visible green dots at direct pin connections. Selectable, deletable, extend into wires when you drag a cell away.
- JJ parameters from technology library: Ic and IcRs values now come from your technology library model. Warning dialog if values are missing.
- Multiple JJ models per library: Add, edit, remove JJ models in Library Properties. Set default model. Per-instance model selection in JJ properties.
- IEC standard JJ symbols: Updated Josephson junction symbols (shunted and unshunted) with filled dots per IEC 60617.
- Library Path Editor: New dialog for managing library paths. Auto-saves changes.
- Waveform viewer export: CSV, PNG, SVG, and publication-quality PDF export with presets.
- Navigate into sub-cells: Go Down (Shift+E) works across libraries.
- Text annotations: Add standalone text labels to schematics (Shift+L).
- In-app feedback: Report bugs and request features directly from Help menu.
Improvements
- Mirror now uses pin center (fixes pin shift on asymmetric symbols)
- Dot decimal separator enforced in all numeric fields
- Status bar shows colored notification bubbles (info/warning/error/success)
- Settings accessible from main window (no need to open a schematic first)
- Output port shortcut: Shift+P
- Dark mode: ribbon bar properly themed, selected tab with white underline
Bug Fixes
- Right-click rotation crash during instance placement
- Mirror/rotation no longer shifts symbol labels
- Waveform viewer dark mode unified with global theme
- Various stability and data integrity improvements
[0.9.5-beta] - 2026-03-07
Added
- Parameter Sweep - Amplitude Scale: PWL/PULSE sources now sweep amplitude scale factor instead of replacing with DC value
- Source type auto-detected from netlist content (ground truth)
- DC sources show DC Value parameter, PWL/PULSE show Amplitude Scale
- Preserves waveform timing and shape while scaling voltage/current values
- Parameter Sweep - Locked Multi-Parameter: Sweep multiple parameters together in lockstep
- All enabled parameters advance together at each step (not combinatorial grid)
- Step count must match across all enabled parameters
- Useful for symmetric parameters (e.g., matching resistors)
- Waveform Viewer - Sweep Legend Controls: Interactive sweep point visibility
- Clickable checkboxes per sweep point to show/hide individual traces
- Hide All / Show All toggle button
- Dynamic color swatches matching selected signal
- Waveform Viewer - X Axis Zoom: Zoom X+ and X- buttons in toolbar
- Margin Analysis: Placeholder menu item under Tools (ribbon and classic menu)
- Documentation: Updated help.html and quickstart.html with sweep features
Fixed
- Sweep Source Type Detection: Source type now read from actual netlist instead of unreliable instance properties
- Handles V/I netlist name prefix mapping (vsrc I32 -> VI32, isrc I5 -> I5)
- Single-parameter rows store correct key in Qt.UserRole (was always defaulting to dc_value)
- Netlist Generator - Connectivity Filter: Fixed inverted filter that kept I/O errors and dropped real errors
- Grid/Snap Toggle: Fixed keyboard shortcut (G key) always turning grid off instead of toggling
- Waveform Viewer - Splitter: Fixed right panel getting crammed on maximize and collapsing on border drag
- Viewer Lifecycle: All viewers now close when schematic editor closes
Security
- UTF-8 Encoding: Added encoding='utf-8' to ~48 file I/O calls across 15 files
- Performance: Replaced O(n) cursor lookup with bisect, list.pop(0) with deque.popleft()
---
[0.9.3-beta] - 2026-01-27
Added
- Instance Color Customization: Visual identification of logic cells in complex circuits
- Right-click instance → Color → Set Color... to customize instance appearance
- Color persists with schematic save/load
- "Highlight All of This Type" for temporary highlighting of all instances of same cell
- Symbol-level default colors supported in symbol.json
- Full undo/redo support
Security
- JSON Schema Validation: All loaded JSON files (symbols, schematics, libraries) now validated
- Prevents malformed data from causing crashes
- Validates required fields, data types, and value ranges
- Clipboard paste validation for cross-application safety
- Input Sanitization: User-provided names sanitized for SPICE/filesystem safety
- Cell names, pin names, net names sanitized to valid identifiers
- Prevents injection attacks in generated netlists
- UTF-8 Encoding: All file operations now use explicit UTF-8 encoding
- Cross-platform compatibility for international characters
- Exception Handling: Bare except clauses replaced with specific exception types
- Improved error messages and debugging
- Path Traversal Protection: Library path resolution validates against directory traversal
- SSL Certificate Verification: License check now verifies SSL certificates by default
- Environment variable FLUXEDA_SKIP_SSL_VERIFY for corporate proxy networks
Fixed
- Undo Race Condition: Flag state now properly restored via try/finally pattern
---
[0.9.2] - 2026-01-24
Changed
- Major wiring system overhaul (internal refactoring)
---
Generated from CHANGELOG.md on build 0.9.9.3-beta